HUBBELL PT2X2GY FLUSH SERIES 2X2 ALUMINUM POKE-THROUGH, GRAY

Grommets

HUBBELL PT2X2GY FLUSH SERIES 2X2 ALUMINUM POKE-THROUGH, GRAY

Part # PT2X2GY
In Stock
Special Price2131 $635.00 Regular Price $645.00
  • Buy 2 for $625.00 each and save 2%
  • Buy 3 for $615.00 each and save 3%
  • Buy 5 for $605.00 each and save 5%
- +

Hubbell aluminum fire-rated poke-through flush floor pedestal. Jack(s): Hubbell HBL5EBK black; category 5e; UL listed; 110 type contacts. Power conductors: #12 AWG THHN stranded copper. Device and cover flap material: thermoplastic. Carpet flange material: painted cast aluminum/solid brass, brushed and lacquered. Conduit tubes: power - 0.75-inches EMT/low voltage - 0.5-inches EMT (two). Listings: outlet box- E31999, fire resistance - R8429. Plenum rating: acceptable for use in environment air handling spaces per NEC article 300.22(C). UL listed and CSA certified. PT2X2FIT through-floor fitting. Non-metallic cover.

Features:

  • Complies with UL 514A requirements for scrub water protection
  • Fire Rating: for use in 1, 1.5, 2, 3 or 4 hour rated unprotected reinforced concrete floors or in 1, 2 or 3 hour rated floors employing Steel floor units and concrete topping (D900 series design)
  • Floor thickness range 2.25-inches (over metal deck) to 7-inches (57.2 to 117.8)
  • UL installation spacing: minimum of 2 feet on centers and not more than one unit per 65 square feet of floor area in each span
  • Cored hole: 3-inches (76.2) diameter

Learn More

Install and service at an additional charge.

Additional Information
More Information
Part # PT2X2GY
MFR HUBBELL
Details

Hubbell aluminum fire-rated poke-through flush floor pedestal. Jack(s): Hubbell HBL5EBK black; category 5e; UL listed; 110 type contacts. Power conductors: #12 AWG THHN stranded copper. Device and cover flap material: thermoplastic. Carpet flange material: painted cast aluminum/solid brass, brushed and lacquered. Conduit tubes: power - 0.75-inches EMT/low voltage - 0.5-inches EMT (two). Listings: outlet box- E31999, fire resistance - R8429. Plenum rating: acceptable for use in environment air handling spaces per NEC article 300.22(C). UL listed and CSA certified. PT2X2FIT through-floor fitting. Non-metallic cover.

Features:

  • Complies with UL 514A requirements for scrub water protection
  • Fire Rating: for use in 1, 1.5, 2, 3 or 4 hour rated unprotected reinforced concrete floors or in 1, 2 or 3 hour rated floors employing Steel floor units and concrete topping (D900 series design)
  • Floor thickness range 2.25-inches (over metal deck) to 7-inches (57.2 to 117.8)
  • UL installation spacing: minimum of 2 feet on centers and not more than one unit per 65 square feet of floor area in each span
  • Cored hole: 3-inches (76.2) diameter

Learn More